Applicable Technical Standard: RS-485
Conductor Material: Oxygen Free Copper Wire
AWG: 22 (7/0.25mm)
Insulation material: Foamed PE
Insulation Colour: White/Blue
Drain Wire: 7/0.20TC
Shielding: Al-foil 100% coverage
Conductor Material: Oxygen Free Copper Wire
AWG: 18 (41/0.16mm)
Insulation material: SR-PVC
Insulation Colour: Black/Red
Outer Diameter: 6.0±0.2mm
Jacket Material: IEC 60332-1 PVC composite
Jacket Colour: Blue/Green stripe
Bend radius: 30mm
ComponentA resistance: Max 55.4 ohms/km at 20°C
ComponentB resistance: Max 21.8 ohms/km at 20°C
Impedance: 100±15Ω
Capacitance: <80PF/m
Voltage rating: 300V
The Kordz ONE 18AWG x 2C + 22AWG x 1P Control Cable is backed by our Lifetime Guarantee that promises maintained product functionality and performance for your lifetime.
The Kordz ONE 18AWG x 2C + 22AWG x 1P Control Cable is engineered for professional building control and automation systems requiring combined low-voltage power and RS-485 communication. It integrates 18AWG stranded conductors for Safety Extra Low Voltage (SELV) power delivery with a 22AWG twisted pair for RS-485 data, supporting common lighting, HVAC, shading and automation architectures.
Designed for efficient installation, the cable features metre markings, an internal nylon ripcord, and a PVC cable rated to IEC60332-1 with CPR Eca compliance. Built for durability and consistent performance in commercial and residential environments, it provides a reliable control-infrastructure foundation for modern building systems backed by the Kordz lifetime warranty.
Safety Extra Low Voltage (SELV) is a term defined by the IEC (International Electrotechnical Commission), which develops international electrical safety standards used widely outside North America. SELV describes extra-low voltage circuits designed to minimise shock risk through voltage limits and protective separation. In the United States, the National Electrical Code (NEC) uses Class 2 circuit classification under Article 725 to define power-limited, low-voltage circuits with similar safety intent. Class 2 circuits are therefore the closest NEC equivalent to SELV, with Class 3 covering higher power-limited applications where applicable.
Yes. ONE 18AWG x 2C + 22AWG x 1P Control Cable supports standard RS-485 signalling and SELV power delivery used by earlier generations of building automation hardware. Compatibility is determined by device requirements, not the cable itself.
Yes. The 22AWG twisted pair is well suited to the linear bus structures typically used for RS-485 control systems. Integrators should follow the device manufacturer’s requirements for termination, maximum bus length and node count.
Although RS-485 supports flexible routing, avoid star wiring unless the connected devices are specifically designed for it, as branching can introduce signal reflections and reduce communication stability.
AS/NZS S008:2010 compliance confirms the cable meets the mandatory safety requirements for customer cabling in Australia and New Zealand. It covers construction, material safety and electrical properties to ensure suitability for low-voltage control installations. This compliance provides integrators with assurance that the cable meets recognised regional safety standards.
The cable’s PVC jacket is engineered to IEC60332-1 flame-retardant requirements and CPR Eca classification, matching the needs of standard control installations. While LSZH is preferred in certain safety-driven environments, PVC remains widely accepted and compliant in general building automation applications.
Yes. Its balanced strand construction, metre markings and internal ripcord support ease of installation in conduits, risers and existing cable pathways commonly found in newbuild, retrofit and renovation environments.
CPR Eca indicates the cable meets specific European Construction Products Regulation fire performance criteria. It is suitable for installations where a basic reaction-to-fire classification is required, supporting compliance in commercial and residential projects.
RS-485 is a balanced differential signalling protocol that benefits from a twisted pair to maintain impedance and reduce noise. The 22AWG pair in this cable is engineered for reliable transmission across typical control bus distances.
The 18AWG stranded conductors are sized for Safety Extra Low Voltage (SELV) power delivery, providing appropriate current capacity and flexibility for control devices. SELV classification supports safety compliance in low-voltage building automation environments.
Using one cable for both power and RS-485 reduces installation complexity, simplifies cable routing and minimises conduit and cable usage. This approach supports an efficient deployment of modern control hardware while maintaining separation of conductors for reliable signalling.
Kordz ONE 18AWG x 2C + 22AWG x 1P Control Cable is designed for building automation systems that use low voltage power and RS-485 communication. This is a common power and control strategy amongst manufacturers such as Lutron, Crestron and Control4 and also includes lighting, shade, HVAC, sensor and control processors across residential and commercial platforms. System compatibility remains dependent on the manufactures specific device requirements.